UP-5008 High-Precision Rotorless Moving Die Rheometer (MDR)

1
MOQ
Negotiable
Price
UP-5008 High-Precision Rotorless Moving Die Rheometer (MDR)
Features Gallery Product Description Chat Now
Features
Specifications
Temperature Control Range: 60℃ — 300℃
Applications: For Plastic, Rubber, Fiber, Foam, Film, And Film
Language: Chinese And English
Torque Unit: N.m, N.inch, Kg.m, Kg.cm, Kg.inch, Lb.m, Lb.inch
Torque Precision: 0.30%
Temperature Fluctuation Range: ±0.15℃
Temperature Resolution: 0.01℃
Service Support: OEM ODM
Torque Resolution: 1/50000
Model NO.: UP-5008
Basic Infomation
Place of Origin: CHINA
Brand Name: YOUBI
Certification: CE, ISO
Model Number: UP-5008
Payment & Shipping Terms
Packaging Details: Professional export packaging
Delivery Time: 5~10 work days
Payment Terms: D/P,T/T,Western Union
Supply Ability: 20 Unit/month
Product Description
Rotorless moving die rheometer (MDR), also called a rotorless curemeter, is the industry-standard instrument for measuring the vulcanization characteristics of rubber compounds. It records the complete cure curve in real time and reports scorch time (ts1, ts2), cure times (t10-t90), minimum and maximum torque (ML, MH) and cure rate indices (Vc1, Vc2) - giving compounders and QC labs a reliable basis for formulation development, process setting and batch release.
Product Overview

Unlike an oscillating-disc rheometer (ODR), the MDR uses a sealed, rotorless die cavity. With no embedded rotor to heat, the specimen reaches test temperature faster and more uniformly, temperature recovery after loading is short, and cured samples are easier to remove. The result is excellent repeatability and reproducible cure data from batch to batch and from lab to lab.

Rotorless moving die rheometer MDR for ASTM D5289 rubber cure testing
Test Standards

ASTM D5289 - Standard Test Method for Rubber Property-Vulcanization Using Rotorless Cure Meters (current edition)
ISO 6502-3:2023 - Rubber - Measurement of vulcanization characteristics using curemeters - Part 3: Rotorless curemeter (general guidance: ISO 6502-1)

Working Principle

An uncured rubber specimen (typically 4-5 cm³, cut with a volumetric sample cutter) is placed between two heated dies forming a sealed, nearly closed cavity, and held at the set test temperature. The lower die oscillates through a small sinusoidal angular arc (standard ±0.5°, optional ±1° or ±3°) at 1.67 Hz (100 cpm), applying a defined oscillatory shear strain to the compound.
The torque transmitted to the stationary die is measured by a high-resolution load cell and recorded as a function of time. As the compound warms and softens, torque falls to its minimum ML (compound viscosity). Once crosslinking starts, torque rises through the scorch point to a plateau or maximum MH (crosslink density / cured stiffness). Compounds prone to reversion show a torque drop after the peak. The resulting torque-time curve (cure curve), together with the temperature curve, is displayed live and stored automatically; its shape depends on the test temperature and on the compound's formulation.

Technical Specifications
Item Specification
Temperature range Ambient to 200 °C
Temperature fluctuation ±0.15 °C
Temperature display resolution 0.01 °C
Heating rate Approx. 15 °C/min
Temperature recovery time < 1.5 min
Temperature units °C, °F, K
Torque range 0-20 N·m (0-200 dN·m)
Torque minimum reading / resolution 0.001 N·m
Torque accuracy ±0.3 % FS
Oscillation amplitude ±0.5° standard; ±1°, ±3° optional
Oscillation frequency / speed 1.67 Hz (100 cpm / 100 r/min)
Data acquisition rate 200 samples/s (200 Hz)
Calculated parameters ts1, ts2, t10, t30, t50, t70, t90, Vc1, Vc2
Report / print contents Date, time, temperature, cure curve, temperature curve, ML, MH, ts1, ts2, t10, t30, t50, t70, t90, Vc1, Vc2
Torque units N·m, dN·m, N·cm, N·in, kN·m, kN·cm, kN·in, kgf·m, kgf·cm, kgf·in, lbf·m, lbf·cm, lbf·in, gf·m, gf·cm, gf·in
Applications

Compound development: evaluating cure packages, accelerators, fillers and anti-scorch agents
Batch-to-batch QC and release testing of mixed rubber compounds
Setting press cure times for compression, transfer and injection molding; avoiding under-cure and over-cure
Tyres, seals & gaskets, hoses & belts, vibration mounts, footwear, wire & cable compounds
Incoming material inspection, supplier qualification and third-party test laboratories

Installation Requirements

A stable single-phase 220 V / 50 Hz supply and clean compressed air at 0.5-0.65 MPa are required; the user supplies an 8 mm OD air tube. Use protective polyester/nylon film and a constant-volume specimen cutter for repeatable results. Allow the dies to stabilise at the set temperature before starting a test.

UP-5008 High-Precision Rotorless Moving Die Rheometer (MDR)
UP-5008 High-Precision Rotorless Moving Die Rheometer (MDR)
FAQ

Q: What is the difference between an MDR and an ODR? 
A: An MDR has no rotor embedded in the specimen. Heating is faster and more uniform, temperature recovery is shorter, and samples are easier to remove. Results from the two instrument types are not directly interchangeable - establish a correlation before transferring QC limits.

Q: Which standard should I follow
A: ASTM D5289 and ISO 6502-3:2023 are the common methods for rotorless curemeters; DIN 53529 and GB/T 9869.3-2025 may be required by regional customers. Agree the standard, test temperature, oscillation arc and frequency with your customer before testing.

Q: What affects repeatability most? 
A: Sample volume and conditioning, die cleanliness/seal condition, and temperature recovery after loading. Use a volumetric cutter and keep the same rest time between mixing and testing.

Ready to specify your cure tester? Contact us for a quotation, the full datasheet and a sample test report.